Fire Fighting Foam System

Foam for Fire

Foam system for fire suppression are commonly installed in industrial areas with Class B fire risks, such as fires involving flammable liquids such as gasoline, oil, thinners, and paint. Unlike hydrants that use pressurized water, foam fire suppression system is the most effective solution for liquid-based fires. Since water and oil do not mix, using water on flammable liquids can spread the fire, making it more dangerous.

Foam for fire suppression works by covering the flammable liquid, cutting off essential fire elements such as air and heat. Foam fire sprinkler system and foam nozzle fire suppression components ensure fast and effective fire control. Additionally, fire fighting foam system is designed to extinguish the fire, while the foam inductor fire suppression mechanism optimizes foam distribution. Foam fire suppression system is the best choice for industrial and oil-related fire hazards, providing increased safety and fire prevention.

Foam Systems Concentrates

Specifications

  • Appearance of foam extinguishing concentrate: Clear Light Yellow
  • Specific Gravity: 1.02 +/- 0.01
  • pH: 7.8 +/- 0.5
  • Viscosity: Maximum 3.0 cps
  • Approvals: UL Listed
sistem foam foam systems

Specifications

  • Capacity of bladder tank foam: 113 or 227 liters (30 or 60 gallons)
  • Tank Material: 316 SS stainless steel (or 304 SS)
  • Hose Reel Type: Continuous flow, reverse rim
  • Reel Material: Mild steel (or 316SS stainless steel)
  • Booster Hose: 1 1/2″ diameter x 30 feet long.
  • Red color. Non-collapsible, textile, braided reinforcement, 13.8 bar (or higher).
  • Prepared Eductor: 227 lpm or 360 lpm (60 or 95 gpm)
  • Eductor Model: 02 PE95-B
  • Eductor Material: Brass
  • Foam Nozzle Fire Fighting Model: 04 HNCG-330B (brass) or 04 HNCG-330A (aluminum alloy)
  • Foam Nozzle Fire Fighting Type: Non-air draw, mist/fog pattern.
  • Valve Type Breaker: Ball, full bore, 1⁄2″ thread Valve Material: Brass
sistem foam foam systems

Specifications

  • Defined by NFPA 11 as a Type II foam discharge outlet for delivering foam to the surface of a flammable liquid
  • Unique Chamber design allows Field Testing without removing the vapor seal assembly
  • Bolted Inspection Access to Interior of Chamber
  • Minimum working pressure is 2.8 bar (40 psi)
  • Maximum working pressure is 7 bar (100 psi)
  • Breakable Glass Vapor Seal at pressures between 0.7 to 1.75 bar. Maximum allowable back pressure at the seal is 0.06 bar
  • Chamber is constructed of Carbon Steel with a #304 Stainless Steel Screen covering the foam air intake
  • Brace connections are ANSI B16.5 Class 150 #FF standard flanges
  • Option of Solid or Spill Deflector Stainless Steel
  • Orifice (calculated to deliver a predetermined foam solution at the available pressure to the chamber flanged inlet)
sistem foam foam systems

Specifications

  • Construction: Brass
  • Water Outlet: Dual 2.5″
  • Maximum Flow: 750 GPM (2,840 lpm)
  • Horizontal Travel: 360º
  • Vertical Height: 130º
  • Vertical Travel Operation: Lever-Mount
  • Base Inlet: 3″ or 4″ ANSI 150# FF Flange
  • Discharge Tip: 2½” NHT male
  • Finish: Red Paint Approvals: FM Approved

Specifications

  • Tank Capacity: 113 or 227 liters (30 or 60 gallons)
  • Tank Material: 316 SS (or 304 SS) stainless steel
  • Hose Reel Type: Continuous flow, reverse rim
  • Reel Material: Mild steel (or 316SS stainless steel)
  • Reinforcement Hose: 1 1/2″ diameter x 30 feet long.
  • Red color. Non-folding textile braid reinforcement, 13.8 bar (or higher).
  • Prepared Eductor: 227 lpm or 360 lpm (60 or 95 gpm)
  • Eductor Model: 02 PE95-B
  • Eductor Material: Brass
  • Nozzle Model: 04 HNCG-330B (brass) or 04 HNCG-330A (aluminum alloy)
  • Nozzle Type: Non-air draw, mist/fog pattern.
  • Valve Type Breaker: Ball, full bore, 1⁄2″ thread Valve Material: Brass