What is Inergen?
INERGEN adalah agen pemadam kebakaran, yang berupa campuran dari gas alam: Nitrogen (N²) 52%, Argon (Ar) 40% dan Karbondioksida (CO²) 8%.
INERGEN works effectively to extinguish fire by lowering the oxygen (O²) concentration in the protected room to a level where fire cannot occur (O² concentration below 15%) while still remaining safe for humans.
Pertanyaan & Jawaban yang Sering Diajukan
Fire Eater has UL-Listed and FM-Approved standardization of the entire Inergen system. PT Adiwarna Anugerah Abadi is the only Fire Eater distributor in Indonesia with experience in consulting, installation, and maintenance of the Inergen System since 2007, and has successfully completed more than 150 Inergen installations throughout Indonesia. Fire protection is essential for the safety of assets and lives. Inergen System is an effective and environmentally friendly solution. It extinguishes fire with natural gas, with no residue, safe for humans and sensitive electronics. In Indonesia, PT Adiwarna Anugerah Abadi is the sole official distributor of Fire Eater. They are experts in consulting, installation, and maintenance of Inergen System. PT Adiwarna Anugerah Abadi has been experienced since 2007. We understand Inergen System well. We have completed more than 150 installations throughout Indonesia. This proves the client's trust in their services and technical expertise. The Inergen System offers a number of significant advantages over conventional fire suppression systems. Some of these include: Choosing PT Adiwarna Anugerah Abadi as a Fire Eater distributor and Inergen System solution provider in Indonesia provides a number of advantages, including: In choosing a fire protection system, especially the Inergen System, PT Adiwarna Anugerah Abadi is present as a reliable and trusted partner in Indonesia. With the status as the sole distributor of Fire Eater, years of experience, and a track record of successful installations, they are ready to provide effective, safe, and environmentally friendly fire protection solutions for your various needs. Trust the protection of your assets and lives to the experts. There are several brands that use INERGEN as a fire extinguisher, one of which is "FIRE EATER", a brand developed by FIRE EATER A/S, Denmark. FIRE EATER A/S was founded in 1974, and is the only company in the world that is 100% focused on using and developing a fire extinguishing system with INERGEN media. Trust in INERGEN as the safest fire extinguishing media in the world, with full scale tests having been carried out more than 5,000 times without any harmful effects on humans, is the reason why FIRE EATER remains and always focuses on INERGEN which delivers FIRE EATER as the market leader of the INERGEN system in the world. Yes, INERGEN is formed from gases that already exist in the atmosphere and are inert, meaning they will not react with fire during a fire to form other compounds. INERGEN has an ODP (Ozone Depletion Potential) = 0 and a GWP (Global Warming Potential) = 0 INERGEN has the characteristic of not damaging electronic equipment or other devices. This is because INERGEN gas does not condense, does not leave residue, and does not conduct electricity, and does not cause chemical reactions when INERGEN is activated. Inergen extinguishes fire by reducing the concentration of oxygen (O2) in the protected room, to a concentration that does not allow for a combustion reaction (fire) to occur but is still safe for humans. INERGEN is an environmentally friendly fire extinguishing medium, composed of Nitrogen (52%), Argon (40%), and CO2 (8%). INERGEN is inert, meaning it does not react in the fire process. INERGEN is not liquid and is non-toxic. INERGEN has unique properties due to the addition of 8% CO2. CO2 gas has a psychological effect that ensures the human body absorbs oxygen. When INERGEN discharges, even though the oxygen level in the room drops below 15%, the 8% CO2 content in INERGEN causes the human body to continue to absorb oxygen so that the oxygen level in the body remains in normal condition. Inergen can be used in a room that is quite closed / quite soundproof. Rooms with lots of ventilation need special attention to ensure the room is quite soundproof.Get to know the Authorized Distributor of Fire Eater in Indonesia: PT Adiwarna Anugerah Abadi, A Reliable Solution for Inergen Fire Protection Systems
Experience and Expertise Since 2007
Over 150 Successful Installations
Why Choose Inergen System from Fire Eater?
Why Choose PT Adiwarna Anugerah Abadi as Your Fire Protection Partner?
Conclusion
Contoh ruangan dengan kelas kebakaran A adalah ruang yang memiliki material padat yang mudah terbakar, semisal ruang medical record atau arsip, dan lain-lain.
Contoh ruangan kelas kebakaran B adalah ruangan yg berisi cairan mudah terbakar, seperti ruang trafo basah, ruangan penyimpanan ethanol atau cairan lainnya yang mudah terbakar, dan lain-lain.
Contoh ruangan kebakaran C adalah ruangan yg memiliki perangkat elektronik yg tersambung ke daya listrik, seperti data-center server, control room, atau panel LVMDP, dan lain-lain.
INERGEN as a fire extinguishing agent registered in NFPA 2001, has many beneficial properties and characteristics, including:
Has electrical conductivity = Zero, so it does not cause damage to electronic equipment in the protected room.
INERGEN as a protection solution for high-value electronic devices, when water media and chemical-based extinguishers will only cause damage.
Leaves no residue that needs to be cleaned off.
Does not cause shock effects due to temperature changes (Temperature Shock).
Has a gas phase, so that INERGEN is able to penetrate all parts and deepest components of the protected room.
Tested safe for humans.
Does not cause decomposition products (e.g.: HF – hydrofluoric acid), which could endanger equipment or people in the protected room.
Recharging is very economical so that real test discharge can be carried out periodically.
INERGEN is an environmentally friendly medium:
Ozone Depletion Potential (ODP) = 0
Global Warming Potential (GWP) = 0
Atmospheric Life Time (ALT) = 0
INERGEN is very good and suitable for use in class A, B, or C fires.
INERGEN is very suitable for use in rooms:
Data Center, Server Room, Electrical Room, Library ARCHIVES, Substation, Switch Gear Room and others.
Explanation of How the Fire-Eater Inergen Fire Suppression System Works
The lnergen Suppression system consists of six parts:
- Control Panel
It is the brain behind an automatic fire suppression system. This control panel coordinates all the actions needed to extinguish the fire. It has the ability to perform self-monitoring, which means that it will periodically and continuously check to determine whether the system is still working properly. If the control panel finds a failure (which may cause the system to malfunction) in the self-monitoring, the panel will indicate a system fault
- Alarm Notification
Alarm notification consists of two types, namely sound and light. Alarm notification equipment includes bells, horn strobes, and warning lamps.
The bell provides sound notification, the horn strobe provides sound and light notification, while the warning lamp provides brief information about the alarm condition that occurs.
The warning lamp placed on the main door will light up when an alarm occurs.
There are two types of warning lamps, namely:
- EVACUATE warning lamp, which is installed indoors as a guide for people to immediately leave the room when an alarm occurs.
- INERGEN DISCHARGE warning lamp, which is installed outside the room as a warning so that people do not enter the fire area when an alarm occurs.
- Detection
The purpose of a fire detection system is to detect a fire as early as possible so that the damage caused by the fire can be minimized. When a fire is detected, a signal from the detector is transmitted to the control panel which then activates the INERGEN system.
There are many types of fire detection. Choosing the right fire detection is important. Choosing the wrong type of fire detection will make the fire difficult or impossible to detect at all.
- Manual Release & Abort Switch
If a fire occurs when there are still people near the room, the automatic extinguishing system can be activated manually using the Manual Release. The manual release position is outside the room, this is intended so that the position of the person who activates the manual release is not in the fire area. When the manual release is activated, make sure the door is closed, so that INERGEN can work optimally to extinguish the fire. While the abort switch is used to temporarily cancel if it is known that the active alarm is a false alarm.
- lnergen Cylinders
To store INERGEN extinguishing agents. The cylinder has a pressure gauge equipped with a low pressure switch to detect and provide automatic notification if there is an indication of low pressure. The common size used is 80 liters. With a pressure of 300 bar, the Inergen Fire-Eater system is more economical and the space required for placing the cylinder is smaller. Equipped with the availability of Fire Eater - Certified Boosting Facility in Indonesia, so that refilling INERGEN 300 bar can be done in Indonesia.
- Pressure Relief
When INERGEN is released into the room, the excess pressure in the room will be released through the pressure relief to prevent over pressure from occurring.